Commercial Door Lock Repair in Burlington, From the Front Entrance to the Back Exit

Commercial Door Lock Repair in Burlington, From the Front Entrance to the Back Exit
On a commercial door, the lock is one of several parts that have to line up before the bolt goes home. The hinges, the closer, the strike in the frame and, on exit doors, the panic bar all play a part, and any one of them wearing out leaves you with a door that won't secure.
The Lock Hut has been doing commercial door lock repair in Burlington, Hamilton and Waterdown for over 30 years. The service list goes past the lock itself, covering closers and exit devices, fob readers, and the doors and frames everything hangs on. Our technicians are bonded and insured, and they're on call 24/7.
Why Won't the Front Entrance Lock at Closing Time?
A front entrance that won't lock at closing has usually moved in its frame. If the key turns but the bolt hits the strike plate instead of going into it, or someone has to push on the door to get it to lock, that's the sign. Front entrances see a lot of traffic, and over time the hinges wear and the door drops a little on the latch side.
Aluminum storefront doors are especially sensitive to this. Many of them use a narrow deadlock with a hook-shaped bolt that swings out into the frame, and there isn't much clearance for it, so a door that has dropped slightly can stop the bolt from throwing.
Closers matter here too, especially this time of year. The fluid in a hydraulic closer thickens in the cold and the door closes slower, so a closer that was set in the summer can leave the door stopping just short of the latch by November. Often a closer adjustment is all it needs.
If the cylinder itself is worn, that's a good time to decide what key runs the front door. We're an authorized Mul-T-Lock and ASSA dealer, and the high security keys we supply for commercial doors can't be duplicated.
Commercial Door Lock Repair on Exit Doors With Panic Bars
On an exit door, the panic bar is the lock. Pushing the bar pulls the latch in, and when it's released, springs inside the device push the latch back out so the door locks when the closer brings it shut. When those parts wear, these are the usual signs.
- The latch comes out slowly, or only partway
- The bar stays down after someone pushes through
- On double doors with vertical rods, the bottom latch drags on the threshold or misses its strike because a rod has bent or slipped out of adjustment
- The latch stays pulled in because the device is still dogged
That last one isn't a broken part, and it's quick to check. Dogging holds the latch back so the door works as a push-pull door during business hours, and a device that's still dogged at closing leaves the door unlocked.
Panic bars and fire door hardware are on our commercial service list, and a bar that has stopped releasing properly is one of the calls our 24 hour emergency service takes.
What If the Door Uses a Fob Reader or an Automatic Opener?
When staff can't get in with a fob, the fault can be on the reader side, meaning the reader itself or its programming, or in the electric strike or lock that actually holds the door. Those are different repairs, and from outside the door they look the same.
Electric locking hardware comes in two types. Fail-secure hardware stays locked when the power goes out, and fail-safe hardware unlocks. If you know how the door behaved during the last power outage, pass that along to the technician, since it narrows down what's installed.
We install, maintain and repair access control systems, whether it's 2 doors or 2,000, and fobs can be programmed for each individual user. New card access can also be tied into the hardware already on the door.
Automatic doors add another variable, since the operator and the lock have to work together. A lock that hasn't released will fight the operator, and an operator that's out of adjustment can keep the door from closing far enough to latch. Our commercial door locksmiths service automatic door systems and can update existing openers when a building's needs change.
What The Lock Hut Repairs on a Commercial Door
These are the commercial locksmith services that come into play on a door that won't secure.
- Door closers and automatic door openers
- Panic bars and fire door hardware
- Doors and door frames
- High security locks and hardware
- Rekeying and re-coding, with on-site key duplication
- Master key systems
- Key cards and fob readers
- File cabinet and desk locks inside the office
When a business entrance won't secure, we dispatch a technician quickly to assess it and do whatever repair or replacement it needs. If keys are part of the problem, rekeying is on the same list, along with on-site key duplication.
Getting Commercial Door Lock Repair in Burlington
Our office is open Monday to Friday, 8:00 AM to 4:30 PM, for commercial door lock repair and the rest of our business locksmith work. An entrance that won't lock after hours can't be left overnight, and that's what our 24 hour locksmith service is for. The Lock Hut covers Burlington, Hamilton, Waterdown, Oakville and the surrounding area, and we also offer security consultations if a repair raises bigger questions about the building's doors.
A repaired commercial door should swing shut and lock on its own every time, without anyone having to pull it closed or lean on it at the end of the day.